Thermax - Item # 12-10KVN-1925, UL 3239 High-voltage Lead Wire(10 KV)- Extruded Modified FEP Insulation
Sitemap
Search Catalog
By Keyword
By Item #
All Categories
UL 3239 High-voltage Lead Wire(10 KV)- Extruded Modified FEP Insulation
All Categories
>
Commercial Wire and Cable
>
UL 1508, 1513, 1516, 1517, 1523, 1558; CSA 105ยบ 150V Wire
>
MIL-W-81822/4 wire-PTFE/polyimide insulation
>
UL 1815; CSA 300V Wire- Extruded PTFE Insulation (Thin wall)
>
LTE high-performance coaxial cables (RG replacement)
>
MIL-W-22759/10 wire - extruded PTFE insulation
>
MIL-W-22759/9 wire - extruded PTFE insulation
>
UL 3239 High-voltage Lead Wire(10 KV)- Extruded Modified FEP Insulation
>
Item # 12-10KVN-1925
Item # 12-10KVN-1925, UL 3239 High-voltage Lead Wire(10 KV)- Extruded Modified FEP Insulation
Printable Page
Email This Page
Save To Favorites
larger image
UL 3239 High-voltage Lead Wire(10 KV)- Extruded Modified FEP Insulation
High-voltage lead wire with extruded modified FEP (Fluorinated Ethylene Polypropylene) insulation. This insulation provides easy, clean stripping with automated equipment.These wires are intended for use in television receivers, transformers, and other demanding high-voltage applications.
Specifications
AWG Size
12
Conductor
Nickel-Plated Copper
Stranding
19/25
Voltage rating - volts
10,000
Temperature rating - °C
200
Conductor Diameter - inches (mm)
.084 (2.13)
Weight - pounds/1000 feet (Kg/1000 M)
7.95 (11.8)
Maximum Resistance - Ω/1000 feet (Ω/KM), @20 °C
1.81 (5.94)
Dielectric withstanding voltage - V
20,000
Spark test
10,000 V RMS AC, 60 Hz.
Insulation
Extruded modified FEP, .018" (.46mm) wall thickness.
Insulation Diameter - inches (mm)
.133 (3.38)
Insulation tensile strength - PSI
2,500
Insulation elongation (% minimum)
150
Ordering Information
Specify Thermax part number, UL or CSA style,and color.